Search...

Table of Contents

Comparison of Legal Requirements: The Machinery Directive vs. the Machinery Regulation

1.2.6. Failure of the power supply (or communication network connection)

Changes

- The requirement is extended to explicitly cover both the power supply and the connection to the communication network for machinery and related products.

- Interruption, re-establishment after an interruption, or fluctuations in the communication connection must not lead to hazardous situations.

- The requirements to prevent unexpected start-up, uncontrolled parameter changes, and the prevention of stop commands thereby explicitly include faults in the communication connection.

- Protective devices must remain fully effective or initiate a stop command even in the event of a fault in the communication connection.

Proposed measures

- Identify which machinery functions depend on communication networks, such as fieldbuses, industrial Ethernet, wireless communication, remote control, and cloud-based services.

- Analyse how interruptions, delays, interference, corrupted data, and reconnection may affect machinery safety.

- Ensure that communication faults do not lead to unexpected start-up, uncontrolled parameter changes, or other hazardous situations.

- Verify that stop functions and safeguards function as intended, even in the event of communication failures.

- Assess the required machinery response to communication failures, for instance through a controlled stop, maintenance of a safe state, or degraded operation.

- Ensure that the restoration of communication does not lead to unexpected restarting or hazardous modifications to the machinery's operating conditions.

- Update the risk assessment to cover relevant communication errors and their potential consequences.

- Verify and validate the machinery's behaviour during communication failures and upon reconnection.

- Where necessary, implement technical protective measures such as communication monitoring, watchdog timers, timeout functions, or other appropriate safeguarding solutions.

Machinery Directive statutory text

1.2.6. Failure of the power supply

The interruption, the re-establishment after an interruption or the fluctuation in whatever manner of the power supply to the machinery must not lead to dangerous situations.

Particular attention must be given to the following points:

— the machinery must not start unexpectedly,

— the parameters of the machinery must not change in an uncontrolled way when such change can lead to hazardous situations,

— the machinery must not be prevented from stopping if the command has already been given,

— no moving part of the machinery or piece held by the machinery must fall or be ejected,

— automatic or manual stopping of the moving parts, whatever they may be, must be unimpeded,

— the protective devices must remain fully effective or give a stop command.

Read more

Machinery Regulation legal text

1.2.6. Failure of the power supply or communication network connection

The interruption, the re-establishment after an interruption or the fluctuation in whatever manner of the power supply or communication network connection to the machinery or related product shall not lead to hazardous situations.

Particular attention shall be given to the following:

(a) the machinery or related product shall not start unexpectedly;

(b) the parameters of the machinery shall not change in an uncontrolled way when such change can lead to hazardous situations;

(c) the machinery or related product shall not be prevented from stopping if the stop command has already been given;

(d) no moving part of the machinery or related product or piece held by the machinery or related product shall fall or be ejected;

(e) automatic or manual stopping of the moving parts, whatever they may be, shall be unimpeded;

(f) the protective devices shall remain fully effective or give a stop command.

Read more

Search...

Table of Contents